I'm planning to run RAID 1 on my PowerEdge 860 server running CentOS 4.4 (320gb x 2 SATA II).
After doing much research, I've decided to go with 3ware 9550sx.
I have some questions regarding installing the 3ware on an existing system with an OS already installed - How do I go about doing it?
I've read that CentOS 4.4 already has the drivers for it.. Do I just configure the RAID config during the boot up?
Is this an overkill for my PE Pentium D 2.8GHZ ?
View 6 Replies
ADVERTISEMENT
May 12, 2009
I downloaded the latest 3dm2 software:
wget [url]
However, after extracting it, when I run the setup (./setupLinux_x64.bin -console) I get "Bundled JRE is not binary compatible with host OS/Arch or it is corrupt. Testing bundled JRE failed."
Can anyone give me the steps for installing 3dm2 on a centos/WHM box?
The card is a 3ware 9690SA.
View 4 Replies
View Related
Feb 16, 2007
I have an existing server running cpanel that I would like to change the hostname on. What I am curious about, is the effects on the rest of the server if I go and change it. From what I can tell, the current host name is being used all over the place, and I don't know if cpanel updates everything on it's own, or if I would need to manually update everything after I change the name.
View 2 Replies
View Related
Nov 9, 2009
Of the three raid card brands, which do you think is best and why?
I'm currently looking for a card that can do both SAS and SATA, and have four internal ports.
View 14 Replies
View Related
Mar 3, 2007
I have installed 3dm for checking 3ware 8086 card status, but when going to [url] it doesnt show anything. It seems cannot connect to 1080 port, even I have turned off the firewall. Have checked in its config file already to make sure the port is 1080
Is there anyone having experience with 3dm software?
View 3 Replies
View Related
Oct 23, 2007
When trying to load an ovzkernel it loses support for the 3ware 8006 controller. As suggested on ovzforums, it says to load the new 3dm2 tools. I tried this but when I try to install it, it says it can't find the 3dm2 binary.
View 0 Replies
View Related
Jul 14, 2008
Not sure if this is too specific for this forum or not, but since I've gotten great advice here in the past I'll give it a shot.
I have a colo'd production server with a 3ware 9500S-12 RAID card and 12 400GB drives attached. The drives form 3 arrays:
1) 2 drive RAID 1 (400GB)
2) 2 drive RAID 1 (400GB)
3) 6 drive RAID 5 (2TB)
plus 2 global hot spares.
For a variety of reasons I need to change this setup so that array 1) and 2) remain as is, and array 3) is removed and those 6 drives replaced with 6 new 750GB drives in JBOD mode. I've copied all the data from the RAID5 array number 3) onto 3 of the new 750 drives (the 2TB array wasn't completely full,) and I have 3 other blank 750GB drives.
What's the best / safest way to do this? Ideally I'd like to remove the 6 old 400GB drives and retain the ability to plug them all back in and get my old array back (if something goes horribly wrong doing the switch.)
Do I need to reboot into 3BM (3ware Bios Manager) to do this, or can I do it from the command line?
Is there any problem with having a drive that already contains data written to it by another system, and bringing it up on the 3ware card in JBOD mode with the data intact? (All filesystems are ext3.) I'm not going to have to reformat the drive, am I?
Is there any problem with the new drives being SATAII (Seagate Barracuda ES 750GB) but the old drives (and I think the 3ware card, and certainly my motherboard) being SATAI? I've read that this should "just work" but of course I am nervous! There are no jumpers I can see on the 750GB drives.
Will it be possible to remove the RAID 5 in such a way that I could plug the drives back in and get the array back?
View 6 Replies
View Related
Jul 24, 2007
I have a bunch of 3Ware 95** RAID arrays with BBUs. Lately the BBUs are sensing high and too high temps a lot.
The dc reports that intake temp is 74 degress and exhaust is 91 degrees. Since the RAID cards and the BBUs are at the back of the machine, its getting more hot air than cool.
View 1 Replies
View Related
Apr 13, 2007
Probably going to give this a shot in the near future anyway, but just wanted to check whether anyone has tried and had success putting either 3Ware 8006-2LP or 9550SX-4LP cards in Dell PowerEdge 860 systems with a couple of SATA drives instead of using the Dell PERC controllers?
View 3 Replies
View Related
Aug 21, 2007
we use 3Ware's 8006-2LP sata raid controller in each of our servers for RAID1. Our servers are all Supermicro boxes with hot-swap driver carriers (ie. the 2 raided drives are in them)
One of the drives appears to be starting to crap itself as smartd is reporting issues (although tw_cli c0 shows the raid to be OK) incl. multi zone errors.
Anyway, I'd like to replace the failing drive before it becomes a real issue so i've bought a replacement (74gb raptor, just like the original) drive.
Now I've never had to replace a failing drive in any of our servers before and I used to think it would be a simple matter of simply popping out the failing drive's carrier, put the new drive in the carrier and stick it back in the server... and the raid controller would do the rest.
Yes a little naive I know but i've never had to do it before so never paid much attention .. Anyway, I've just read and re-read the 3ware docs for my controller and their instructions are VERY VAGUE ... however I do get the feeling that the process is move involved ie. I need to tell the controller (via cli or 3dm) to first 'remove' the failing drive from the raid ..and then add a new drive and then rebuild
However there is one catch .. 3dmd/3dm2 has NEVER worked on our (centos 4) servers - 3dmd crashes regularly and 3dm2 never worked. So yes I am stuck with the 3ware cli ... which I don't mind as long as someone can tell me the sequency of commands I need to issue
As this point I'm thinking what I need to do via cli is
1) tell raid controlloer to remove the failing drive on port 0
2) eject the drive carrier with the drive in question
3) insert new drive in carrier and re-insert into server
4) using tw_cli tell the controller to add the new drive to the array and to rebuild the array
Am I anywhere close to being correct? I'm sure there are some of you out there who've done this countless times before with the 3ware controllers and hotswap drive carriers ..
View 4 Replies
View Related
Aug 21, 2007
Just bought a new OEM 3ware 9500S-12 SATA RAID Controller from ebay for $250, is it a good deal? Does it work with SATA-II HDDs?
View 1 Replies
View Related
Jun 28, 2009
I'm seeing the following from dmesg:
Quote:
3w-9xxx: scsi0: AEN: INFO (0x04:0x0053): Battery capacity test is overdue:.
When I'm in the CLI console (tw_cli) and tries to test the battery, I'm seeing the following:
Quote:
//vpsXX1> /c0/bbu test
Depending on the Storsave setting, performing the battery capacity test may
disable the write cache on the controller /c0 for up to 24 hours.
Do you want to continue ? Y|N [N]:
This is a live production server with client VPSs on it. Anyone here actually did 3ware battery test before on production system? Is it ok to do this? I'm seeking someone actually performed test operation before, not from someone just assumes it will be ok.
View 5 Replies
View Related
Jun 6, 2009
I have a 3ware 9650SE-24M8 RAID Controller. It was working fine for a few days and today while I was changing the RAID configs and installing different OSs, it just stopped working. Now when I boot my machine up it does not even detect any hard drives or RAID controller. I looked inside the box and the LED light on the RAID controller that is usually solid green is now blinking red. I googled for solutions but all searches lead me to useless information such as blinking red lights on the server case.
View 12 Replies
View Related
Apr 6, 2008
After seeing a topic a week or go discussing RAID cards I decided to give a hardware raid card a go to see if the performance will increase in one of our boxes.
Just for the simplicity of the test, I have put them into a RAID0 formation for purely performance tests and no redundancy. I choose a 3ware RAID card and went for the 2 port 8006-2LP option rather than the 9600 (as they had the 8006-2lp and risers in stock and what I've always been told is that SATA1 and SATA2 is really a selling point rather than any performance increase but we will leave that argument there). Because we run mainly Windows systems, I have put on Windows Server 2003 x64 R2. What I am finding after installing it all is it seems pretty "slow".
The rest of the hardware is a Dual, Quad Xeon (E5410x2), 8GB ram on a Tyan motherboard. Hard drives are 160GB Western Digital 7200 RPM so I can't see quite why it feels like its not running at a peak level.
Does anyone have any applications or software to give this RAID array a test as I really don't want to order any more or roll them out on to the network to find that software raid would be a better improvement. I did try a burn in app which tests everything but it according to the 20 seconds I ran it, in average it only transferred at 2mbs.. That cant be right..
I think one possibility is the RAID drivers arn't installed correctly as its still coming "Unknown Devices" in Device Manager and it seems It wont let me manually install the drivers for the 3ware device as it doesn't like the OS even though I have the correct ones and it installed Windows with it fine (a bit longer than normal anyway)
View 14 Replies
View Related
Jan 29, 2007
I have configured a Xen setup on a dual xeon system with a 3ware 8506 2 ports sata controller.
Array is configured in raid1 and I am using LVM.
I get really slow accesses on the virtual machines, when I create a big ext3 system, the system is nearly freezing.
View 2 Replies
View Related
Oct 19, 2009
i want to use q9550 with 8G RAM,
install on X7SBL-LN2,
and use for 500G SATAII to do raid 10,
about Adaptec 2405SAS and 3Ware 9650SE-4LPML,
which one will get better performance?
View 14 Replies
View Related
Nov 12, 2008
I am not sure exactly which model is in my server, but I know it is in the 3ware 8xxx line.
What is my best option to be alerted to a drive failure. I am running a Raid 1 setup.
I went to 3ware's sight, and wasn't sure exactly which software to download/install.
I am on Centos 5.2 32bit and have Cpanel/WHM installed.
View 4 Replies
View Related
Mar 30, 2008
I am currently trying to transition a website from one CMS to another.
I need to configure and build the new CMS so that it retains the same features of the previous CMS.
I don't want to interrupt service to the website, thus I need to build the new one offline and then switch the two.
Can a domain server with the same domain structure of the WWW be run on a LAN?
I was thinking of configuring a FreeBSD server with apache on a private IP LAN.
Then I would run a DNS server to emulate the internets domain structure (.com, .net and .org).
View 3 Replies
View Related
Jul 27, 2008
I have this strange issue,
There are few domains with few email accounts with some existing emails, like
user@domain1.com having 60 mails in inbox
user2@domain1.com having 125 mails in inbox
user@domain2.com having 80 mails in inbox
user2@domain2.com having 380 mails in inbox
And many more.
Now these existing emails are to be forwarded to onespecificmailid@some-remote-domain.com
How to automate this?
There are hundreds of other mail accounts too which should not get disturbed/touched.
Each existing mail should be forwarded as normally incoming mails are forwarded.
We have root access and server specs are:
WHM 11.23.2 cPanel 11.23.4-R26138
CENTOS Enterprise 5.2 i686 on standard - WHM X v3.1.0
Any idea how to do that?
View 9 Replies
View Related
Dec 3, 2008
I've tried posting 3 tickets (2 support and 1 billing) and so far non of them was answered. 1st ticket I've posted was 11/18/2008 and until now, no response.
Has anyone seen their support and billing in action??? my last ticket was for billing canceling my account. They've got good prices but lacking of support people... too bad
View 12 Replies
View Related
Nov 2, 2009
What should I do ?
Dear Site Point , im looking for some advice on which steps I should now take with my online business which really needs SEO performance to be the best it can but with my current hosting situation and existing customers using a live system things might be complicated.
Im using a hosting company in Europe to run UK Based websites which I have read makes no difference to SEO aslong as you use the Google webmaster tools and define the location. The hosting company offers the use of adding multiple domains to one account which I currently have about 50 so in theory 50 sites are using the same IP Address , I have just read that sites with backlinks to the same IP Address gives your site a big ' 0 ' for SEO backlink results, is this true ? so having " website designed by " has no effect on each of your clients pages.
I have looked into to becoming a reseller on a UK based hosting company but the problem is my customers use one master SQL database for all the products as all my customers even though different businesses all sell similar types of products so they all use the same SQL tables as it made no sense setting up a seperate database for each customer on the same hosting , each customer uses a shared control panel with sessions so everything is secure.
So Should each customer have a reseller hosting account with a seperate database / domain etc which could be a security risk as potentially they could resell the website software.
or
Keep the virtual overseas hosting (cheaper) and keep all my customers on one account and purchase a dedicated ip address for a primary domain that I sell from to try and boost SEO back links ?
or.....maybe someone could advise something better ? more stable ?
View 2 Replies
View Related
May 3, 2008
Current BB: readybb.com/cindysommer
Current host: readyBB
My technical skills: only enough to be dangerous
Thanks in advance to anyone who can help.
My current host is not satisfactory. Support is practically non-existant. I need to know if there is such a thing as a host that will provide transfer services as I do not have the technical ability to do it myself.
I would think the ideal situation would be to copy everything to the new host first, but as much as I've read and read about this for months, I still do not trust myself to do it.
View 14 Replies
View Related
Jan 4, 2007
I have a site but it was corrupted due to server problem with host. I have a back-up of DB in phpMySQL.
I am now installing the same script in new server and the site is now running.
The problem is, I want to use my back-up database and replace the existing one. How to do this?
View 2 Replies
View Related
Nov 6, 2008
How to create a simple template using existing VPS?
I can create simply compressing the dir of an active VPS?
Example: tar -zcvf template.tar.gz /vz/private/VEID
View 3 Replies
View Related
Oct 5, 2008
I'm an existing customer of Hosting Company X and notice that they have recently launched an offer that is a higher config than what I have right now, at the same price.
When asked about it, I was refused the higher config citing that new offers are not applicable for existing customers. I've been with them for over a year and have been experiencing very good support from them, but this one issue baffles me.
Why are existing customers less important?
View 14 Replies
View Related
Mar 1, 2007
I'm having a problem in my cPanel/WHM on a RHEL3. I installed a webcam and I'm trying to upload the images to an specific directory. The process is simple: the webcam uploads a temporary file to avoid not having a correct JPG version of the image and then renames the temporary file to the JPG. Problem is PureFTD won't premit this last step, renaming, but does permit overwriting an existing file at upload time.
I've been looking in hte PureFTD documentation and can't seem to find the correct configuration flag. I'm probably missing something, any ideas?
View 2 Replies
View Related
Jan 7, 2013
I'm trying to integrate the websocket into existing application.Based on my search, i found a websocket module to do this, but it isn't updated yet. URL...
Any chance that the module will be included in Apache ? Also i found in StackOverflow conversation that Apache httpd wasn't design to maintain persistent connection, is that true ? Using WebSocket on Apache server. Should continue using Apache websocket module or using separate websocket server ?
View 6 Replies
View Related